Indoor Surveillance
Public Buildings

Application Overview

Public Buildings require extensive surveillance systems as they may be prone to attack, robbery or theft of information. A reliable, redundant and secure monitoring system is critical for these applications which is operable 24/7.

Key Considerations

  • Redundant ring topology with millisecond scale network recovery for maximum uptime.
  • Compact design for indoor and outdoor storage.
  • Long-haul fiber connectivity to provide high-bandwidth speeds for both on premise and remote monitoring.
  • Intelligent powered device alive-check and monitoring for scheduling with energy saving which provides burden-less maintenance.

Key Volktek Benefits

  Feature Benefit
Reliability Redundant Power Remains On During Power Failure Redundant power sources (15VDC or battery back-up) keep the devices operational during power failures.
Availability Ring Redundancy Remains Connected If Active Link Fails Combine multiple network connections in parallel to increase the throughput beyond a single connection, provide link redundancy and reduce ISP network stability issues.
Performance Quality of Service (QoS) Define the Critical Networks Specific networks can be prioritized, optimizing the network performance and bandwidth utilization.
VLAN Connect Remote Devices Network administrators can partition the networks to match the functional and security requirements of their systems without having to run new cables or make major changes in the current network infrastructure.
Storm Control Prevent LAN Traffic Storms Prevents the traffic on a LAN from being disrupted by a broadcast, multicast, or unicast storm on a port, reducing the system bandwidth requirements and saving CAPEX.
Security Device Locking Last Mile of Protection By enabling the Device Lock feature, the switch will not function in any network other than its configured network.
e-mail Alarm Triggered Events Alert Via Email

1) Notify the administrator if real-time problems occur such as firmware or configuration changes, device status, link connectivity status, etc.

2) Help administrators to quickly identify, isolate and resolve network issues.

Management Link Layer Discovery Protocol (LLDP) Access Device and Network Information

1) Rapidly react to physical link failure and recover immediately 

2) Provide an alternate pathy link to support continuous transmission.

PoE ON / OFF + PD Alive Check Intelligent PoE+ for Powered Devices PoE switches can enable or disable the power supply to the powered devices.  The powered ports can send keep-alive checking packets to the devices to increase system reliability.

 

Application Diagram

PRODUCT

COMPARE(0)

INQUIRE

We use cookies to provide the services and features offered on our website, and to improve our user experience. By using this website, you consent to the use of cookies.

OK